Fault Finding
Display Messages
Displays Description
There is no mains power to the control panel and the alarm system is now
running on its standby battery. The system will also generate a chime tone
every minute to warn you that the fault exists, to silence the chime tones
simply enter your passcode. If the mains power is not restored you may not
be able to set the alarm system. If the fault persists the standby battery will
eventually run flat. Contact your alarm company for further advice.
A full alarmhas occurred from a detection circuit (circuit 05). This message
is normally display after unsetting the alarm system. Before the system can
besetagainthealarmsystemmustbereset,see“ResettingAfteranAlarm”
on page 10.
Anauxiliaryalarmhasoccurredfromadetectioncircuit(circuit06).Thetype
ofalarmissilentandwillactivatetheappropriateoutputs.Toresetthealarm
simply enter your passcode followed by [ESC].
Thecontrolpanelauxiliaryorbelltampercircuitshavebeenactivated.Ifthe
faultisnotclearedyouwillnotbeabletosetthealarmsystem.Tosilencethe
alarmsimplyenter yourpasscode. Contactyouralarmcompanyforfurther
advice.
Thealarmsystemstandbybatteryhasdevelopedafault,normallybecause
the system mains power is not present. If the fault is not cleared you will not
be able to set the alarm system. To silence the alarm simply enter your
passcode. Contact your alarm company for further advice.
One or more circuits have been isolated from the system. For full details
refer to “Isolate / Re-Instate Shunt Group” on page 18.
Apasscodehas beenincorrectly enteredmore thanfourtimesata remote
keypad (keypad 02). To silence the alarm enter a correct passcode. To
reset the alarm simply enter your passcode follows by [ESC].
A delayed full alarm has occurred from a detection circuit (circuit 05). This
message is normally display after unsetting the alarm system. Before the
system can be set again the alarm system must be reset, see “Resetting
After an Alarm” on page 10.
An entry time out alarm has occurred from a detection circuit (circuit 01).
Thisisnormallycausedwhentheentryprocedureisstartedandthesystemis
not unset before the timer expires. Before the system can be set again the
alarm system must be reset, see “Resetting After an Alarm” on page 10.
36
DELAY ALARM 05
17:30 01 Jan
DELAY ALARM 05
17:30 01 Jan
AC OFF
17:30 01 Jan
AUX/BEL TAMPER
17:30 01 Jan
BATTERY FAULT
17:30 01 Jan
CCTS ISOLATED
17:30 01 Jan
ALARM 05
17:30 01 Jan
AUXILIARY 06
17:30 01 Jan
CODE TAMPER 02
17:30 01 Jan
DELAY ALARM 05
17:30 01 Jan
CODE TAMPER 02
17:30 01 Jan
ENTRY ALARM 01
17:30 01 Jan