11681330 Issue 1 Page 3
Glows steadily if:
a) A fault or tamper circuit is active while the system is unset.
b) The system needs an engineer or remote reset.
c) A telephone line fault is present.
The 9940 keypad provides the following keys:
9 - 0 Used to key in access codes or select programming commands.
Used to enter programming and setting/unsetting commands.
Used to set the system with individual zones (including 24 hour zones)
temporarily omitted.
ABCD Level or partition setting keys
In addition, some control units may support the Dual Key Alarm function to allow
users to start an alarm by pressing the following pairs of keys:
1 + 3 Panic alarm
4 + 6 Medical assistance
7 + 9 Fire alarm
Technical Description
Specification
Sales number 9940EN or 9941EN
Security Grade 3
Environmental Class II
Operating temperature -10° to +55°C
Humidity 96% RH
Dimensions 115mm W, 115mm H, 24mm D
Weight 0.2 kg
Current consumption (9940) 30mA max continuous backlight off
70mA max continuous backlight on.
(9941) 20mA max continuous backlight off
60mA max continuous backlight on.
Compliance EN51031-1
For further detail and Declaration of Conformity please
go to www.coopersecurity.co.uk.
CE Telefication
Inputs
Name Used For:
Panic External wired PA button.
Ext Tamper External tamper switch or wiring.
ET Exit Terminate button.
Data, CLK Signal from control unit keypad bus.
12V, 0V DC power supply.