Chapter 9 How to Use the XSCF Web 9-13
System and Domain Operation
TABLE 9-6 lists the function used for the system as a whole and individual domains. Select
[Operation]-[Domain Operation]-[Domain Power] in the Menu tree.
Note – In the M3000 server, the number of the target domain is one. Domain ID is fixed to
00.
TABLE 9-7 lists the functions used for specifying each domain mode. Select
[Operation]-[Domain Operation]-[Domain Mode Configuration] in the Menu tree.
TABLE 9-6 System and Domain Operation
Function Remarks
System power on/off Specifies the system power on/off.
This function is equivalent to the poweron(8) /
poweroff(8) commands.
Domain power-on/off Specifies the domain power on/off.
This function is equivalent to the poweron(8) /
poweroff(8) commands.
Reset System reset, XIR reset and panic for the domain are
performed. This function is equivalent to the reset(8)
command.
Send break Specifies the send break.
This function is equivalent to the sendbreak(8) command.
TABLE 9-7 Domain Mode Configuration
Function Remarks
Domain mode configuration/display Sets a hardware initial diagnostic level. Suppresses the
send break, Host watchdog, and automatic boot
functions. Also, displays the host ID, the domain mode
status, and domain ethernet address (mac address).
This function is equivalent to the setdomainmode(8)
and showdomainmode(8) commands.
On the XSCF Web, you cannot display/configure the
CPU operational mode. Use the showdomainmode(8)
and setdomainmode(8) commands.